null

Outlet Spacers & Shims

Outlet spacers, also called electrical shims or shimming fasteners, fill the gap between a wiring device and its box when the box sits behind the finished wall. They let the device rest firmly at the wall surface, so outlets don't wobble, cover plates sit straight and the drywall around the box doesn't crack.

Choose by the problem you're fixing

The problem

What to use

Outlet, GFCI or switch sits behind the wall surface (drywall cut too wide, tile or paneling added)

UniShim 632 on the 6-32 device screws

Light fixture bracket won't sit flush with the ceiling or wall

UniShim 832 on the 8-32 bracket screws

The box itself is set back further than code allows

A box extender or extension ring. Spacers move the device, not the box.

Adjustable spacers vs. plastic shims vs. box extenders

 

UniShim adjustable spacer

Plastic tear-off shims

Box extender

Depth control

Dial in any depth

1/8" steps, stacked

Fixed ring depth

Parts per screw

1

Several

1 ring per box

Stays put while you tighten

Yes, the catch pin locks it

Loose pieces can shift or slip

Yes

Material

Metal

Plastic

Plastic or metal

Holds its depth over time

Yes, metal won't compress

Plastic can compress under screw pressure, letting the device loosen

Yes

Reusable

Yes, readjust anytime

Rarely

Yes

What you stock

One part for every depth

Strips to build different stacks

Rings in several depths

Fixes a box set back past code

No, use an extender

No

Yes

Bottom line: if the box is within code and only the device needs to come forward, UniShim is the simplest fix: one metal part per screw, set to the exact depth and locked in place. Shop UniShim 632 for outlets and switches or UniShim 832 for light fixtures.

Frequently Asked Questions

Q: What is an outlet spacer?

A: An outlet spacer is a part that fits on a receptacle or switch mounting screw, between the device and the electrical box. It fills the gap when the box is recessed, so the device sits firmly at the finished wall surface.

Q: Why is my outlet sunk into the wall?

A: Usually tile, paneling or an extra layer of drywall was added over the old box, or the drywall opening was cut larger than the device's mounting ears. With nothing solid to rest on, the device sinks and wobbles.

Q: How far can an electrical box be set back from the wall?

A: Under NEC 314.20, a box in a noncombustible wall such as drywall, tile or plaster can be set back no more than 1/4 inch. In wood or other combustible surfaces, the box must be flush or stick out. Always check your local code.

Q: Should I use an outlet spacer or a box extender?

A: Use an outlet spacer when the box is within the allowed setback and only the device needs to come forward. Use a box extender when the box itself is set back further than code allows.

Q: Do plastic outlet shims compress over time?

A: They can. Plastic held under constant screw pressure can compress, which lets the device loosen and wobble again. Metal spacers like UniShim won't compress, so they hold their depth.

Q: What screw size do outlets and switches use?

A: Standard receptacles and switches mount with 6-32 screws, which fit UniShim 632. Light fixture brackets commonly use 8-32 screws, which fit UniShim 832.